Fluid-Structure Interaction in Biological Media / FSI
Saeed Nahidi; Alireza Hossein-Nezhad; Nasser Fatouraee; Zahra Heidari
Volume 7, Issue 2 , June 2013, , Pages 107-120
Abstract
Blood flow parameters are affected by position and shape of the accumulation of low density lipoprotein (LDL) in the layers of the arterial wall, and this phenomenon itself is influenced by infiltration flow of the blood. In this paper, in order to investigate the effect of wall flexibility on the infiltration ...
Read More
Blood flow parameters are affected by position and shape of the accumulation of low density lipoprotein (LDL) in the layers of the arterial wall, and this phenomenon itself is influenced by infiltration flow of the blood. In this paper, in order to investigate the effect of wall flexibility on the infiltration flow in a pulsatile non-Newtonian blood flow in a symmetric carotid artery stenosis with a two flexible and porous layers, a finite element model with Porous Fluid Structure Interaction (PFSI) method was used and the results were compared to the porous rigid model. Study parameters were investigated in three different stenosis severities. Comparison of the presented results using PFSI model with those of Porous Rigid model showed about 22% decrease in wall shear stress in the stenosis region, about 20% increase in filtration velocity in the pre- and post-stenosis regions of the porous layer, but a slight difference in filtration velocity in the stenosis region.
Fluid-Structure Interaction in Biological Media / FSI
Saeed Nahidi; Alireza Hossein-Nezhad; Nasser Fatouraee; Zahra Heidari
Volume 6, Issue 1 , June 2012, , Pages 71-79
Abstract
Hemodynamic parameters are always affected by stenosis severity of arterial and these parameters in their turn have influence on the development of atherosclerosis. In this paper, By considering three different stenosis severity, the effects of wall porosity assumption on the hemodynamic parameters of ...
Read More
Hemodynamic parameters are always affected by stenosis severity of arterial and these parameters in their turn have influence on the development of atherosclerosis. In this paper, By considering three different stenosis severity, the effects of wall porosity assumption on the hemodynamic parameters of a stenosed artery with a two-layer flexible wall (intima-media, adventitia), in which inner layer (intima-media) assumed porous, is numerically investigated, using Porous Fluid Structure Interaction (PFSI) model. Blood is assumed as an incompressible non-Newtonian fluid with pulsatile flow condition. In this investigation, the results show that the permeability assumption has much influenced on the hemodynamic characteristics so that the comparison of the results using PFSI with those of a non-porous model show 6% decrease in shear stress, 30% increase in displacement and more than 72% increase in effective stress in the porous layer.